Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Validation of a novel imaging approach using multi-slice CT and cone-beam CT to follow-up on condylar remodeling after bimaxillary surgery

  • Laura Ferreira Pinheiro Nicolielo*
  • , Jeroen Van Dessel
  • , Eman Shaheen
  • , Carolina Letelier
  • , Marina Codari
  • , Constantinus Politis
  • , Ivo Lambrichts
  • , Reinhilde Jacobs
  • *Autor correspondiente de este trabajo

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

28 Citas (Scopus)

Resumen

The main goal of this study was to introduce a novel three-dimensional procedure to objectively quantify both inner and outer condylar remodelling on preoperative multi-slice computed tomography (MSCT) and postoperative cone-beam computed tomography (CBCT) images. Second, the reliability and accuracy of this condylar volume quantification method was assessed. The mandibles of 20 patients (11 female and 9 male) who underwent bimaxillary surgery were semi-automatically extracted from MSCT/CBCT scans and rendered in 3D. The resulting condyles were spatially matched by using an anatomical landmark-based registration procedure. A standardized sphere was created around each condyle, and the condylar bone volume within this selected region of interest was automatically calculated. To investigate the reproducibility of the method, inter- and intra-observer reliability was calculated for assessments made by two experienced radiologists twice five months apart in a set of ten randomly selected patients. To test the accuracy of the bone segmentation, the inner and outer bone structures of one dry mandible, scanned according to the clinical set-up, were compared with the gold standard, micro-CT. Thirty-eight condyles showed a significant (P<0.05) mean bone volume decrease of 26.4%±11.4% (502.9 mm3±268.1 mm3). No significant effects of side, sex or age were found. Good to excellent (ICC>0.6) intra- and inter-observer reliability was observed for both MSCT and CBCT. Moreover, the bone segmentation accuracy was less than one voxel (0.4mm) for MSCT (0.3 mm±0.2 mm) and CBCT (0.4 mm±0.3 mm), thus indicating the clinical potential of this method for objective follow-up in pathological condylar resorption.

Idioma originalInglés
Páginas (desde-hasta)139-144
Número de páginas6
PublicaciónInternational journal of oral science
Volumen9
N.º3
DOI
EstadoPublicada - 1 sep. 2017

Nota bibliográfica

Publisher Copyright:
© The Author(s) 2017.

Huella

Profundice en los temas de investigación de 'Validation of a novel imaging approach using multi-slice CT and cone-beam CT to follow-up on condylar remodeling after bimaxillary surgery'. En conjunto forman una huella única.

Citar esto