Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Mechanical properties of thermoformed and direct-printed aligner materials after immersion in 37 °C water: a 14-day in vitro study

  • Rodrigo Oyonarte*
  • , Isabel Margarita Lagos
  • , Francisca Vidaurre L
  • , Tomás Parada B
  • , Alberto del Real
  • , Soonho Jang
  • , Harim Jeong
  • , Jiho Lee
  • , Jinhong Min
  • , Tarek M. Elshazly
  • , Jung Yul Cha
  • , Hoon Kim*
  • *Autor correspondiente de este trabajo

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

1 Cita (Scopus)

Resumen

This study compared the mechanical properties of direct-printed dental aligner materials made from 3D-printed resins TC-85, TR-07, and TA-28 with those of two conventional thermoformed materials—Zendura-A and Zendura-Flx—to evaluate their performance under simulated physiological conditions. Test specimens were immersed in a 37 °C water bath for 12 different durations: 0, 5, and 30 min; 1, 3, 6, and 9 h; and 1, 3, 7, and 14 d. Tensile tests were performed using a universal testing machine (Zwick Z010, Zwick, Ulm, Germany) to measure the Young’s modulus (MPa), elongation at break (%), and tensile force (N) at strains of 1%, 2%, and 3%. After 14 d of immersion, TC-85, TA-28, and TR-07 exhibited forces in the range of 4.04–7.24 N at 1% strain and 7.30–13.48 N at 3% strain, while Zendura A and Zendura FLX exhibited forces of 26.26–32.91 N at 1% strain and 32.91–65.23 N at 3% strain. The Young’s modulus and UTS results exhibit a trend similar to that of the tensile force. Direct-printed aligners exhibited a 25.3% (TC-85) increase in elongation at break after 30 min, whereas thermoformed aligners exhibited a 5.5% reduction. Direct-printed resins, such as TC-85, TA-28, and TR-07, with temperature-responsive viscoelastic behavior, exhibited statistically significant differences from thermoformed aligner materials, delivering lower mechanical loads that could favor a more suitable orthodontic force profile for clear aligners.

Idioma originalInglés
Número de artículo5864
Páginas (desde-hasta)5864
PublicaciónScientific Reports
Volumen16
N.º1
DOI
EstadoPublicada - 21 ene. 2026

Nota bibliográfica

Publisher Copyright:
© The Author(s) 2026.

Huella

Profundice en los temas de investigación de 'Mechanical properties of thermoformed and direct-printed aligner materials after immersion in 37 °C water: a 14-day in vitro study'. En conjunto forman una huella única.

Citar esto