TY - JOUR
T1 - Clinical evaluation of posterior restorations over wet and dry dentin using an etch-and-rinse adhesive
T2 - A 36-month randomized clinical trial
AU - González, Claudia C.
AU - Ñaupari-Villasante, Romina
AU - Dos Santos de Castro, Andrea
AU - Mendez-Bauer, Luján
AU - Dávila-Sanchez, Andrés
AU - Aliaga-Sancho, Paulina
AU - Gutierrez, Mario Felipe
AU - Reis, Alessandra
AU - Loguercio, Alessandro D.
N1 - Publisher Copyright:
© 2024 Elsevier Inc.
PY - 2024/4
Y1 - 2024/4
N2 - Objectives: To evaluate the clinical performance of posterior restorations over wet and dry dentin with an etch-and-rinse adhesive after 36 months of clinical service. Methods: Forty-five participants were recruited, each one had at least two posterior teeth that needed restoration. Ninety restorations were placed on Class I or Class II cavities. For the restoration protocol, a simplified etch-and-rinse adhesive (Adper Single Bond 2) was applied over wet (WD) or dry dentin (DD) and later restored with a bulk-fill composite (Filtek Bulk Fill) under rubber dam isolation. Each restoration was evaluated using the World Dental Federation (FDI) criteria after 6, 12, and 36 months of clinical service, regarding the following principal restoration characteristics: postoperative sensitivity, marginal discoloration, marginal adaptation, fracture of material and retention, and recurrence of caries. Kruskal Wallis analysis of variance rank (α = 0.05) and Kaplan-Meier survival analysis were used for statistical analysis. Results: After 36 months of clinical evaluation, no significant difference between groups was observed in each FDI criterion (p > 0.05). Twenty restorations (WD=10, DD=10) showed minor marginal staining, and twenty-two restorations (WD=11, DD=11) presented small marginal adaptation defects (p > 0.05). Four restorations were lost (WD = 2, DD = 2) and the fracture rates (95% confidence interval) were 94.9% for each one, without significant difference between wet and dry dentin (p > 0.05). Significance: The degree of dentin moisture does not seem to affect the clinical performance of a simplified etch-and-rinse adhesive in posterior restorations when the adhesive is applied vigorously over the dentine surface.
AB - Objectives: To evaluate the clinical performance of posterior restorations over wet and dry dentin with an etch-and-rinse adhesive after 36 months of clinical service. Methods: Forty-five participants were recruited, each one had at least two posterior teeth that needed restoration. Ninety restorations were placed on Class I or Class II cavities. For the restoration protocol, a simplified etch-and-rinse adhesive (Adper Single Bond 2) was applied over wet (WD) or dry dentin (DD) and later restored with a bulk-fill composite (Filtek Bulk Fill) under rubber dam isolation. Each restoration was evaluated using the World Dental Federation (FDI) criteria after 6, 12, and 36 months of clinical service, regarding the following principal restoration characteristics: postoperative sensitivity, marginal discoloration, marginal adaptation, fracture of material and retention, and recurrence of caries. Kruskal Wallis analysis of variance rank (α = 0.05) and Kaplan-Meier survival analysis were used for statistical analysis. Results: After 36 months of clinical evaluation, no significant difference between groups was observed in each FDI criterion (p > 0.05). Twenty restorations (WD=10, DD=10) showed minor marginal staining, and twenty-two restorations (WD=11, DD=11) presented small marginal adaptation defects (p > 0.05). Four restorations were lost (WD = 2, DD = 2) and the fracture rates (95% confidence interval) were 94.9% for each one, without significant difference between wet and dry dentin (p > 0.05). Significance: The degree of dentin moisture does not seem to affect the clinical performance of a simplified etch-and-rinse adhesive in posterior restorations when the adhesive is applied vigorously over the dentine surface.
KW - Clinical trial
KW - Composite restoration
KW - Dental adhesive
KW - Dental bonding
KW - Dentin
UR - http://www.scopus.com/inward/record.url?scp=85185569278&partnerID=8YFLogxK
UR - https://www.mendeley.com/catalogue/d3674283-50ff-3465-9738-68b23b925f29/
U2 - 10.1016/j.dental.2024.02.009
DO - 10.1016/j.dental.2024.02.009
M3 - Article
AN - SCOPUS:85185569278
SN - 0109-5641
VL - 40
SP - 619
EP - 628
JO - Dental Materials
JF - Dental Materials
IS - 4
ER -