TY - JOUR
T1 - Six-year clinical evaluation of a copper-containing universal adhesive in non-carious cervical lesions
T2 - A split-mouth double-blind randomized clinical trial
AU - Ñaupari-Villasante, Romina
AU - Carpio-Salvatierra, Byron
AU - Matos, Thalita P.
AU - de Freitas, André
AU - Aliaga-Galvez, Romina
AU - Gutiérrez, Mario F.
AU - Binz-Ordonez, María Cristina
AU - Reis, Alessandra
AU - Loguercio, Alessandro D.
N1 - Publisher Copyright:
© 2024
PY - 2025/2
Y1 - 2025/2
N2 - Objectives: To evaluate the clinical performance of a universal adhesive system containing 0.1 % copper nanoparticles (CuNp) in non-carious cervical lesions (NCCLs) after 6 years. Material and methods: Two hundred and sixteen restorations (n = 54) were randomly placed in 36 participants with at least four NCCLs. Groups included: ER-Cu (adhesive in etch-and-rinse strategy with CuNp), ER-Ct (etch-and-rinse without CuNp), SE-Cu (self-etch with CuNp), and SE-Ct (self-etch without CuNp). Restorations were evaluated at baseline and after 1, 3, 4, and 6 years using the FDI and USPHS criteria. Primary outcome: fracture of material and retention. Examiners and patients were blinded to group assignment. Results: After 6 years, 104 restorations were analyzed (ER-Cu 24, ER-Ct 29, SE-Cu 27, SE-Ct 24). Fourteen restorations loss retention (ER-Cu 6, ER-Ct 1, SE-Cu 2, SE-Ct 7). Retention rates (95 % confidence interval) were 79.3 % (61.6 – 90.1) for ER-Cu; 97.0 % (83.3 – 99.4) for ER-Ct; 93.1 % (78.1 – 98.1) for SE-Cu; and 76.7 % (59.1 – 88.2) for SE-Ct, with statistical differences between SE-Cu vs. ER-Ct, and SE-Ct vs. ER-Ct (p < 0.05). Thirty-one restorations (ER-Cu 6, ER-Ct 5, SE-Cu 9, SE-Ct 11) showed minor marginal staining, and forty-one restorations (ER-Cu 8, ER-Ct 10, SE-Cu 11, SE-Ct 12) presented minimal marginal adaptation defects (p > 0.05). No significant differences were found for other secondary parameters (p > 0.05). Conclusion: This is the first 6-year clinical trial showing the long-term behavior of a universal adhesive system in NCCLs. The addition of CuNp does not affect the clinical performance of the universal adhesive.
AB - Objectives: To evaluate the clinical performance of a universal adhesive system containing 0.1 % copper nanoparticles (CuNp) in non-carious cervical lesions (NCCLs) after 6 years. Material and methods: Two hundred and sixteen restorations (n = 54) were randomly placed in 36 participants with at least four NCCLs. Groups included: ER-Cu (adhesive in etch-and-rinse strategy with CuNp), ER-Ct (etch-and-rinse without CuNp), SE-Cu (self-etch with CuNp), and SE-Ct (self-etch without CuNp). Restorations were evaluated at baseline and after 1, 3, 4, and 6 years using the FDI and USPHS criteria. Primary outcome: fracture of material and retention. Examiners and patients were blinded to group assignment. Results: After 6 years, 104 restorations were analyzed (ER-Cu 24, ER-Ct 29, SE-Cu 27, SE-Ct 24). Fourteen restorations loss retention (ER-Cu 6, ER-Ct 1, SE-Cu 2, SE-Ct 7). Retention rates (95 % confidence interval) were 79.3 % (61.6 – 90.1) for ER-Cu; 97.0 % (83.3 – 99.4) for ER-Ct; 93.1 % (78.1 – 98.1) for SE-Cu; and 76.7 % (59.1 – 88.2) for SE-Ct, with statistical differences between SE-Cu vs. ER-Ct, and SE-Ct vs. ER-Ct (p < 0.05). Thirty-one restorations (ER-Cu 6, ER-Ct 5, SE-Cu 9, SE-Ct 11) showed minor marginal staining, and forty-one restorations (ER-Cu 8, ER-Ct 10, SE-Cu 11, SE-Ct 12) presented minimal marginal adaptation defects (p > 0.05). No significant differences were found for other secondary parameters (p > 0.05). Conclusion: This is the first 6-year clinical trial showing the long-term behavior of a universal adhesive system in NCCLs. The addition of CuNp does not affect the clinical performance of the universal adhesive.
KW - Clinical trial
KW - Copper nanoparticles
KW - Longevity
KW - Non-carious cervical lesion
KW - Universal adhesive system
UR - http://www.scopus.com/inward/record.url?scp=85212871474&partnerID=8YFLogxK
U2 - 10.1016/j.jdent.2024.105532
DO - 10.1016/j.jdent.2024.105532
M3 - Article
AN - SCOPUS:85212871474
SN - 0300-5712
VL - 153
JO - Journal of Dentistry
JF - Journal of Dentistry
M1 - 105532
ER -